Caterclad®

|
Developed in conjunction with Senior Environmental Health Officers, Caterclad® is the wall finish you can be sure is proven safe and hygienic, where it counts the most - where food is prepared or provided. That is why Caterclad® is a popular choice in hotels and restaurants, schools, hospitals and food processing plants. Caterclad® conforms to EU and UK requirements in respect of wall finishes in food environments. Caterclad® is the only PVC hygienic wall lining system that has the EU Reports PrEN 13823 exposure to thermal attack and PrEN ISO 11925-2: 1999 direct impingement of flame. Caterclad® has Warrington Fire Research Centre Reports confirming a pass in both BS476 Part 6 - Fire Propagation - and BS476 Part 7 - Surface Spread of Flame. Caterclad® also complies with Paragraph A12(b) of Approved Document B, Fire Safety in Building Regulations 1991. |
|
Caterclad® has Certifications for Marine and Off-Shore use from the Lloyd's Register and we, at Interclad, constantly monitor our products so that the highest standards of hygiene and performance are upheld.
Frequently used in pubs and cafés, takeaways and service stations, as well as by the Armed Services, Caterclad's cost-effective and maintenance free wall surfacing is a proven winner - it doesn't chip, is impervious, impact-resistant and very, very easy to clean. It can be installed over a variety of surfaces such as ceramic tiling or paint, plaster or plasterboard, plywood or MDF, metal or brick, blockboard or blockwork. Caterclad® only needs surface preparation in cases where walls are unsound or uneven.
The thermoformed corners eliminate places where mould, mildew or bacteria can accumulate and Caterclad® can be easily integrated with flooring systems.
Technical Specification
| Sheet Dimensions | 2500 X 1220 x 2.5mm |
| 3050 X 1220 x 2.5mm | |
| Colour | matt white |
| Surface Spread of Flame | BS476 Part 7 1997 Class 1 |
| Impact Strenghth izod notch hardness | 2.1 |
| Co-efficient of thermal expansion | 3.7 x 10-5 |
| Specific Gravity | 1.4 |
| Thermal conductivity | 1.05 |
| Maximum service temprature | 65°C; |
| Elastic Modulus at bend | 4.5 x 10-3 |
Caterclad Certification and Reports
PrEN 13823 exposure to thermal attack - Warres 116582 (EU Test)PrEN ISO 11925-2 1999 direct impingement of flame - Warres 116603 (EU Test)
BS 476: Part 7: 1997 Surface Spread of Flame Class 1 Warres 102778
BS 476: Part 6: 1989 Fire Propagation Pass Warres 102779
Compliance as defined in Paragraph A12(b) of Approved
Document B, ‘Fire Safety’ in Buildings Regulations 1991
EEC Commission Directive 90/128/EEC Food Contact Safe Plastic
SGS Certification CP43044/BW/98
Lloyds Register of Shipping Certification SAS F020203/A1 for Marine & Off-Shore use
Architectural Specification
| Supply and install Caterclad® to a finished height of - insert height - using Cladfix® panel adhesive; thermoformed internal and external corners with Cladfix® Co-extrusions between panels. Provide an Interclad® Assurance on completion. | |
| Caterclad/Mediclad | m2 |
| Caterclad®/Mediclad® (less than 300mm) | m |
| Thermoformed internal/external corners | m |
| Waterproof sealant at abutments | m |
| Cut-outs for service | no |
Standard Available Trims
| Panel Joint (H) 2.5m / 3.0m | ![]() |
| End Stop (J) 2.5m / 3.0m | ![]() |
| End Trim (F) 2.5m / 3.0m | ![]() |
| Modified Panel Joint 2.5m only | ![]() |